Shrimp glutamate dehydrogenase (GDH) Elisa kit instructions

Shrimp glutamate dehydrogenase (GDH) Elisa kit instructions

This kit is for research use only.

Detection range: 96T

0.2U / L -10 U / L

purpose of usage:

This kit is used to determine the activity of glutamate dehydrogenase (GDH) in shrimp serum, plasma and related liquid samples.

Experimental principle

Shrimp glutamate dehydrogenase (GDH) Elisa kit instructions This kit uses the double antibody sandwich method to determine the level of shrimp glutamate dehydrogenase (GDH) in the specimen. With purified shrimp

Glutamic acid dehydrogenase (GDH) antibody is coated on the microplate to make a solid phase antibody, and glutamine is added to the monoclonal antibody-coated microwells in turn

Acid dehydrogenase (GDH), then combined with HRP-labeled glutamate dehydrogenase (GDH) antibody to form antibody-antigen-enzyme label

Antibody complex, after thorough washing, add substrate TMB to develop color. TMB turns into blue under the catalysis of HRP enzyme, and

Under the action of acid, it turns into the final yellow. The color depth is positively correlated with glutamate dehydrogenase (GDH) in the sample.

Measure the absorbance (OD value) at 450nm with a microplate reader, and calculate the shrimp glutamate dehydrogenase in the sample by the standard curve

(GDH) active concentration.

Kit composition

1 30 times concentrated washing solution 20ml × 1 bottle 7 stop solution 6ml × 1 bottle

2 Enzyme label reagent 6ml × 1 bottle 8 standard (16U / L) 0.5ml × 1 bottle

3 Enzyme label coated plate 12 wells × 8 strips 9 standard dilutions 1.5ml × 1 bottle

4 Sample diluent 6ml × 1 bottle 10 instructions 1 copy

5 Developer A solution 6ml × 1 bottle 11 2 sealing film

6 Developer B liquid 6ml × 1 / bottle 12 1 sealed bag

Specimen requirements

1. Specimens are extracted as soon as possible after collection, and extraction is performed according to relevant literature, and experiments should be conducted as soon as possible after extraction. If not

Perform the test immediately. The specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided

2. The samples containing NaN3 cannot be detected because NaN3 inhibits horseradish peroxidase (HRP) activity.

Steps

1. Dilution of standard products: this kit provides one original standard product, the user can dilute in a small test tube according to the following chart

release.

8 U / L No. 5 standard 150μl original standard added 150μl standard dilution

4 U / L No. 4 standard 150μl No. 5 standard added 150μl standard diluent

2 U / L No. 3 standard 150μl No. 4 standard added 150μl standard diluent

1 U / L No. 2 standard 150μl No. 3 standard added 150μl standard diluent

0.5 U / L No. 1 standard 150μl No. 2 standard added 150μl standard dilution

2. Add sample: set up blank wells (the blank control wells do not add samples and enzyme reagents, the rest of the operation is the same), standard well

Sample hole to be tested. Add 50μl of the standard on the enzyme-coated plate accurately, and add 40μl of sample diluent to the sample well.

Then add 10μl of the sample to be tested (the final dilution of the sample is 5 times). Add the sample to the bottom of the well of the microtiter plate

Do not touch the wall of the hole, shake gently to mix.

3. Incubation: seal the plate with the sealing film and incubate at 37 ° C for 30 minutes.

4. Mixing solution: Dilute 30 times concentrated washing liquid with distilled water 30 times and reserve

5. Washing: Carefully peel off the sealing film, discard the liquid, spin dry, fill each well with washing liquid, let stand for 30 seconds and then discard, so

Repeat 5 times and pat dry.

6. Add enzyme: add 50μl of enzyme label reagent to each well, except blank well.

7. Incubation: The operation is the same as 3.

8. Washing: The operation is the same as 5.

9. Color development: add 50μl of developer A to each well, and then add 50μl of developer B, mix gently, and develop color at 37 ℃ in the dark

10 minutes.

10. Termination: Add 50μl of stop solution to each well to terminate the reaction (at this time, the blue color turns to yellow).

11. Determination: Measure the absorbance (OD value) of each well in sequence with the blank air conditioner at zero and 450nm wavelength. Determination should be terminated

Within 15 minutes after the solution.

Summary of operating procedures:

Calculation

Taking the concentration of the standard as the abscissa and the OD value as the ordinate, draw a standard curve on the coordinate paper, according to the sample

The corresponding concentration of OD value is found by the standard curve; multiplied by the dilution factor; or the standard concentration and OD value are used to calculate the standard

The linear regression equation of the quasi-curve, the OD value of the sample is substituted into the equation, the sample concentration is calculated, and then multiplied by the dilution factor,

This is the actual concentration of the sample.

Precautions

1. The kit should be taken out of the refrigerated environment and equilibrated at room temperature for 15-30 minutes before it can be used.

After use, the slats should be stored in sealed bags.

2. Crystals may be precipitated in the concentrated washing liquid, which can be heated and dissolved in the water bath during dilution, and the results will not be affected during washing.

3. The sample adder should be used in each step of sample addition, and its accuracy should be regularly checked to avoid test errors. One sample loading time is best

Control within 5 minutes, if the number of specimens is large, it is recommended to use a volley gun to add samples.

4. Please make the standard curve at the same time of each measurement, it is better to make the complex hole. If the content of the test substance in the specimen is too high (sample OD value

Is greater than the OD value of the first well of the standard product), please dilute it with a certain multiple (n times) of the sample diluent before measuring.

When calculating, please multiply the total dilution factor (× n × 5).

5. The sealing film is limited to one-time use to avoid cross contamination.

6. Please keep the substrate away from light.

7. Strictly follow the instructions, and the test results must be determined based on the reading of the microplate reader.

8. All samples, washing liquid and various wastes should be treated as infectious agents.

9. The components of different batches of this reagent shall not be mixed.

Storage conditions and validity period

1. Kit storage :; 2-8 ℃.

2. Validity: 6 months

Human Ornithine decarboxylase (ODC)

FOR RESEARCH USE ONLY

Assay range: 10 U / L -320 U / L 96 determinations

Purpose

For the quantitative in vitro determination of ODC concentrations in Human serum,

cell culture supernates and other biological fluids

Principle of the assay

The kit assay Human ODC level in the sample, use Purified Human ODC antibody to

coat microtiter plate wells, make solid-phase antibody, then add ODC to wells, Combined ODC

antibody which With HRP labeled goat anti-Human become antibody-antigen-

enzyme-antibody complex, after washing Completely, Add TMB substrate solution, TMB

substrate becomes blue color At HRP enzyme-catalyzed, reaction is terminated by the addition

of a sulphuric acid solution and the color change is measured spectrophotometrically at a

wavelength of 450 nm. The concentration of Human ODC in the samples is then determined by

comparing the OD of the samples to the standard curve.

Materials provided with the kit

1 wash solution 20ml × 1bottle 7 Stopp Solution 6ml × 1 bottle

2 HRP-Conjugate reagent 6ml × 1 bottle 8 Standard (640U / L) 0.5ml × 1 bottle

3 Microelisa stripplate 12well × 8strips 9 Standard diluent 1.5ml × 1bottle

4 Sample diluent 6ml × 1 bottle 10 Instruction 1

5 Chromogen Solution A 6ml × 1 bottle 11

Closure plate

membrane

2

6 Chromogen Solution B 6ml × 1 bottle 12 Sealed bags 1

Specimen requirements

RD

1. extract as soon as possible after Specimen collection, and according to the relevant

literature, and should be experiment as soon as possible after the extraction. If it can't,

specimen can be kept in -20 ℃ to preserve, Avoid repeated freeze-thaw cycles.

2. Can't detect the sample which contain NaN3, because NaN3 inhibits HRP active.

Assay procedure

1. Dilute and add sample: Dilute Original density Standard as follow table:

320U / L 5 Standard 150μl Original density Standard + 150μl Standard diluent

160U / L 4 Standard 150μl 5 Standard + 150μl Standard diluent

80U / L 3 Standard 150μl 4 Standard + 150μl Standard diluent

40U / L 2 Standard 150μl 3 Standard + 150μl Standard diluent

20U / L 1 Standard 150μl 2 Standard + 150μl Standard diluent

2.add sample: Set blank wells separately (blank comparison wells don't add sample and

HRP-Conjugate reagent, other each step operation is same). Testing sample well. Add Sample

dilution 40μl to testing sample well, then add testing sample 10μl (sample final dilution is

5-fold), add sample to wells, don't touch the well wall as far as possible, and Gently mix.

3.Incubate: After closing plate with Closure plate membrane, incubate for 30 min at 37 ℃.

4.Configurate liquid: 30-fold (or 20-fold) wash solution diluted 30-fold (or 20-fold) with distilled

water and reserve.

5.washing: Uncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer

to every well, still for 30s then drain, repeat 5 times, dry by pat.

6.add enzyme: Add HRP-Conjugate reagent 50μl to each well, except blank well.

7.incubate: Operation with 3.

8.washing: Operation with 5.

9.color: Add Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the

light preservation for 15 min at 37 ℃

10.Stop the reaction: Add Stop Solution50μl to each well, Stop the reaction (the blue color

change to yellow color).

11.assay: take blank well as zero, Read absorbance at 450nm after Adding Stop Solution and

within 15min.

Steps description

Standard, Sample diluent

Add Standard, Sample diluent, incubate for 30 min at 37 ℃.

Wash 5 time, Add HRP-Conjugate reagent, incubate for 30 min at 37 ℃.

Wash 5 times, Add Chromogen Solution A and B, incubate for 30 min at 37 ℃.

Add Stopp Solution

Read absorbance at 450nm within 15 min

calculate

Calculate

Take the standard density as the horizontal, the OD value for the vertical, draw the

standard curve on graph paper, Find out the corresponding density according to the sample

OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line

regression equation of the standard curve with the standard density and the OD value, with the

sample OD value in the equation, calculate the sample density, multiplied by the dilution factor,

the result is the sample actual density.

Important notes

1. The kit takes out from the refrigeration environment should be balanced 15-30 minutes in

the room temperature, ELISA plates coated if has not use up after opened, the plate should

be stored in Sealed bag.

2. washing buffer will Crystallization separation, it can be heated the water helps dissolve

when dilute. Washing does not affect the result.

3. add Sample with sampler Each step, And proofread its accuracy frequently, avoids the

experimental error. add sample within 5 min, if the number of sample is much, recommend

to use Volley.

4. if the testing material content is excessively higher (The sample OD is bigger than the first

standard well), please dilute Sample (n-fold), Please diluente and multiplied by the dilution

factor. (× n × 5).

5. Closure plate membrane only limits the disposable use, to avoid cross-contamination.

6. The substrate evade the light preservation.

7. Please according to use instruction strictly, The test result determination must take the

microtiter plate reader as a standard.

8. All samples, washing buffer and each kind of reject should according to infective material

process.

9. Do not mix reagents with those from other lots.

Storage and validity

1.Storage: 2-8 ℃.

2.validity: Six months shrimp glutamate dehydrogenase (GDH) Elisa kit instructions

We are often asked, [What is the best pouch packaging for my product?"  That`s a great question that has many different variables and options to it.  As experts in the Flexible Packaging business, which includes pouch packaging, we are happy to answer this question.  There are many options to choose from.  But first, I have a few general statements.  Flexible packaging, such as Stand Up Pouches, spouted stand bags for liquids, and even rollstock is made from multiple layers of engineered barrier film which are laminated together to create a structure that is incredibly strong and durable so it can stand if necessary, withstand puncture, and have the barrier properties to protect the contents from moisture, vapor, odor, even UV rays. This combination of strength and protection makes pouch bags very popular for packaging retail products.

Some of the more popular styles of pouch packaging include:

Stand Up Pouches

Gusseted Bags

Flat Barrier Bags

Spouted Stand Up Pouches

Flat Bottom-Flexible Box Bags

Zipper Packaging Bags

Rollstock


Packaging Pouches

Stand Up Pouch,Retort Pouch,Pouch Packing,Vacuum Pouch

Chaozhou Chao'an Xinmin Food Packaging Co., Ltd. , https://www.somipack.com

Posted on