How to deal with unexpected situations in the salt spray test chamber

The salt spray test chamber is one of the important test equipments for artificial three-proof (wet heat, salt spray, mold). We may encounter various unexpected situations during the test, such as sudden interruption of the test, then encounter this How should the situation be solved? Look at the small series to answer your questions.

The sudden interruption of the test during the salt spray test is generally divided into two cases. The special requirements mentioned in 3.12 of GJB150.11A-2009 are as follows:

1. Under test is interrupted. In the event of an unexpected test interruption, resulting in a test condition below the specified value and exceeding the tolerance, a full visual inspection of the test piece shall be performed and a technical assessment of the effect of the test interruption on the test result shall be made. The test piece was stabilized under the test conditions and the test was restarted from the interruption point.

2. The test was interrupted. In the event of an unexpected test interruption, resulting in a test condition above the specified value and exceeding the tolerance, the test conditions shall be stabilized within the tolerance and maintained at this level until a comprehensive visual inspection and technical evaluation can be performed to determine the test. Interruption affects the test results. If the visual inspection or technical evaluation concludes that the test interruption does not adversely affect the final test results, or that the effect of the interruption is negligible, the test conditions before the interruption shall be re-stabilized and the test shall continue from the point in time when the tolerance is exceeded. . Otherwise, restart the test with a new test piece.

盐雾试验箱之如何处理突发状况

Cotton Tote Bag

Cotton Tote Bag,Pure Cotton Tote Bag,Shopping Bag Custom,Cotton Bag Customized

Shenzhen Xinmingcai Clothing Co,.Ltd , https://www.xmcsz.com

Posted on